WELCOME TITUS® TWISTER®!
WELCOME TITUS® TWISTER®!
The HydroACT analyzer offers a wide range of customizable capabilities to suit any user’s requirements: from a basic analyzer with a single sensor and analog output to a more comprehensive solution consisting of a controller with multiple sensors, several chemical feed control outputs, and digital communications (Modbus or PROFIBUS). Other optional features include analog and digital I/O, data logging, and remote access over LAN or GSM modem.
The PC3400 is the first Particle Counter specifically designed for use in drinking water treatment plants and includes an uncomplicated calibration process for the end user. Simply access the calibration features via the front panel keypad and perform automatic sizing calibration of any selected size range in seconds. No computer or software is required. With the PC3400, the customer is no longer dependent upon the manufacturer for calibration of their instrument.
The HydroACT Analyzer with DuraTrac 4 Streaming Current Sensor is Chemtrac’s most reliable and accurate Streaming Current Monitor, providing unique and versatile capabilities for optimizing coagulant or polymer dosing. With improved Streaming Current measurement capability, expansive I/O, state of the art chemical feed logic, and the ability to monitor additional parameters key to coagulation (e.g. pH, UV254, NTU), this revolutionary product offers a dependable, comprehensive, and scalable approach for tackling virtually any water treatment scenario.
The Laboratory Charge Analyzer (LCA) is an essential coagulation optimization tool for the water treatment professional. The LCA allows the user to determine an ideal coagulant dosage needed to achieve optimum NTU and TOC reduction in less than 5 minutes. The LCA can also be used to determine the do. With improved Streaming Current measurement capability, expansive I/O, state of the art chemical feed logic
The UVP1000 portable UV254 monitor can quickly and accurately test UV 254nm in the field within minutes. The meter can provide test results in both UV transmittance (UVT) and UV absorbance (UVA). The UVP1000 has been designed to cope with the harsh conditions encountered in the field. However, the extreme accuracy of the UVP1000 makes it a valuable addition to any water analysis laboratory. Calibration is as simple as the push of a button, and our patent-pending technology maintains calibration over multiple samples.
Free Chlorine
Amperometric Analyzer
Free Chlorine Analyzer with pH
Compliant with EPA Method 334.0 amperometric Free Chlorine analysis • Low maintenance costs • Real-time measurement • Specialized electrode protection technology with membrane cap • pH auto compensation function calculates accurate free chlorine concentration • Extremely short polarization time, 30 minutes to 90% of signal strength
Having a big sale, on-site celebrity, or other event? Be sure to announce it so everybody knows and gets excited about it.